Web4 de mar. de 2024 · The refrigeration plants on merchant vessels play a vital part in carrying refrigerated cargo and provisions for the crew on board. In reefer ships, the temperature of the perishable or temperature sensitive … WebHigh discharge pressure . Condenser coil dirty. 7.10. Condenser fan rotating backwards. 7.11. Condenser fan inoperative. 7.11. Refrigerant overcharge or noncondensibles. 7.7.1. Discharge pressure regulator valve defective. 7.21. Discharge service valve partially closed. Open. Suction modulation valve malfunction. 7.19. Low suction pressure
High discharge pressure reefer
Did you know?
Web4 de mar. de 2024 · High pressure or HP cut out: As the name suggests, the high pressure cut out activates and trips the compressor when the discharge side pressure increases above the limit value.The HP cut out is not auto reset and has to be done manually. The reason behind it is to manually attend the fault which is leading to rise in … WebWe had a unit having a high discharge temperature which stops the unit and go out of range.here is the troubleshooting video I did in fixing this unithttps:/...
Web3 de out. de 2024 · 109 check high discharge pressure sensor; 110 check suction line sol circuit; 111 unit not configured correctly; 112 check remote fans; 113 check elerctric heat circuit; 114 multiple alarms- can not run; 115 check high pressure cut out switch; 116 check high pressure cut in switch; 117 auto switch from diesel to electric Web00012 High Coolant Temp Unit will restart*, report reactivation. 00013 High Discharge Pressure Unit will restart*, report reactivation. 00014 High A/C Amps Unit will restart*, …
Web7.9.2 Replacing High Pressure Switch. 1. Remove the refrigerant charge. 2. Disconnect wiring from defective switch. The high pressure switch is located on the discharge connection or line and is removed by turning counterclockwise. 3. Install a new high pressure switch after verifying switch settings. 4. WebGot a call for a reefer unit that quit running and has a high pressure code active here’s a diy on understanding what that means and how to repair or bypass
Web*IF YOU ARE IN THE TNT PHASE OF TRAINING DOWNLOAD THE CHECKLIST*http://bit.ly/2PO3aq6In this video I will show you how to fix alarm code …
Web22 de abr. de 2024 · The objective of any refrigeration system is to collect heat from a low temperature area and move it to a high temperature area. Refrigerant is a substance that acts as a cooling agent by absorbing and giving off heat. Usually there are two types of refrigeration systems commonly encountered : namely the vapor compression cycle … phone number 980 area codeWeb21 de jan. de 2008 · CTC high discharge I ... Code 10 on SR truck units with open drive scrolls same thing, the high pressure cutout, ... By REEFER-TEK in forum Transport Replies: 0 Last Post: 05-12-2007, 07:25 PM. cooling &freezing comp. By afeef in forum Industrial Compressors how do you pronounce eatenWebRefrigeration systems operating at a higher-than-normal discharge pressure can be the result of several different issues. Depending on the degree of increase, the system could … phone number aaa cooperWebAssociate Degree. 6,648 satisfied customers. I have a 2004 Thermo SB 190. Shooting codes 13-11-2 6 4 I. I have a 2004 Thermo King SB 190. Shooting codes 13-11-2 6 4 I … how do you pronounce ecclefechanWeb7.9.2 Replacing High Pressure Switch. 1. Remove the refrigerant charge. 2. Disconnect wiring from defective switch. The high pressure switch is located on the discharge … phone number aadhar card updateWebI get that, but I have 5 reefer like this thermo king and carriers and whn I set 34 it will stay on 34-35 after little time, but this reefer in continuous mode will come to 42 and stay there, … how do you pronounce ecclesiologyWeb12 de ago. de 2012 · Rheem units need the blade to sit fairly high, and yes, if the blade is not correct, in both rotation, and pitch and depth, and speed, you can indeed get high pressure trip. also the coils could need cleaning. also the compressor itself could be damaged and cause a high pressure trip. the system needs to be checked out by a … phone number aaa hanford ca